Finden Sie schnell pt100 kabelfühler für Ihr Unternehmen: 351 Ergebnisse

BIRTFLEX 552-H HSLH

BIRTFLEX 552-H HSLH

HALOGEN-FREE, FLEXIBLE CONTROL CABLES These halogen-free flexible connecting cables are more thinner and lighter than the other control cables and used in mechanical engineering for instrumentation and control equipment for tooling machinery production lines and flexible applications for free movement without tensile load and dry, ambitient, wet places. These cables are used at covered areas, plants and in the environments which have no corrosive gases are emitted in the event of fire. In case of fire, these cables inhibit the propagation of the flames whereby the development of smoke is extremely low. These cables are not used for outdoor or underground installation. Conductor: Flexible copper wires, plain;, IEC 60228 Class 5, TS/DIN EN 60228 Class 5 Insulation: HFFR compound, TI6, TS/DIN EN 50367-7 Core identification: Acc. to TS/DIN EN 50334 black cores with, white numerals with green/yellow from 3 cores Lay-up: Cores laid up in layers of optimum pitch Outer sheath: HFFR compound, TM7, TS/DIN EN 50367-8, Halogen-free flame retardant, -OZ:Numbered cores black Sheath colour: RAL 7001,Grey Standard: TS HD 21.14 S1 & TS HD 21.13 S1, (Designed according to) Insulation resistance: Min. 20 MΩ.km Rated voltage: 300 / 500V Test voltage: 2000 V Temperature range: Fixed: - 30 oC ~ + 70 oC, Mobile: - 5 oC ~ + 50 oC Min. bending radius: Fixed: 6 x D, Mobile: 12,5 x D Smoke density test: IEC 61034-2 & TS/DIN EN 61034-2 Halogen-free properties test: IEC60754-1/2 & TS/DIN EN 50267-2 Flame test: IEC 60332-3 & TS/DIN EN 50266-2-4
BIRTFLEX 572 SY-JB

BIRTFLEX 572 SY-JB

PVC INSULATED, STEEL WIRE BRAID CONTROL CABLES These steel wire braided flexible connecting cables which core colours difference from each other are more used in mechanical engineering for instrumentation and control equipment for tooling machinery production lines and flexible applications for free movement without tensile load and dry, ambitient, wet places. The cores up to 1,0 mm2 service voltage is 300/500 V and 1.5 mm2 and after 2.5 mm2 cores service voltage 450/750 V. The armour above the inner sheath, steel wire braid serves as protection against mechanical traverse loads and act as a magnetic screen against interference. The galvanised steel wires are free of corresion and oxidation. These cables are not used for outdoor or underground installation. Conductor: Flexible copper wires, plain; IEC 60228 Class 5, TS/DIN EN 60228 Class 5 Insulation: PVC compound , TI2 Core identification: Coloured cores Lay-up: Cores laid up in layers of optimum pitch Inner Sheath: PVC compound, RAL 7001,Grey Armour: Braid of galvanised steel wires, approx. %85 cove. Outer sheath: PVC compound, TM2 Sheath colour: RAL 7001,Grey or Transparent Standard: DIN VDE 0281-5 – VE 0281-13VDE 0245-102 (Designed according to) Insulation resistance: Min. 50 MΩ.km Rated voltage Uo/U: ≤ 1,0 mm2 : 300 / 500V, ≥ 1,5 mm2 : 450 / 750 V Test voltage: 4000 V Temperature range: Fixed: - 40 oC ~ + 70 oC; Mobile: - 5 oC ~ + 70 oC Min. bending radius: Fixed: 4 x D; Mobile: 12,5 x D Flame retardance test: IEC 60332-1 & EN 50265-2-1
BIRTFLEX-EF 656

BIRTFLEX-EF 656

PVC INSULATED, , EXTRA FLEXIBLE, HIGH TEMPERATURE OIL RESISTANT CONTROL CABLES These high temperature 90oC grade, oil resistance high-flexibility control cables are designed for applications where cable flexibility is needed. These cables are used for instrumention ,control and connecting of control units in mechanical tool construction, conveyor and assembly lines, production lines, any areas where continuous bending loads for free movement without tensile load forced movement in the cable trailing chain is required. Conductor: Extra flexible copper wires, plain; IEC 60228 Class 6, TS/DIN EN 60228 Class 6 Insulation: PVC compound ,90o grade, TI3 Core identification: Acc. to TS/DIN EN 50334 black cores with white numerals with green/yellow from 3 cores Lay-up: Cores laid up in layers of shorten optimum pitch Separator: Textile bandaging Outer sheath: Oil and flame resistant PVC compound, 90oC Sheath colour: RAL 7001,Grey Standard: TS HD 21.13 S1, DIN VDE 0281-13TS HD 21.12 S1, DIN VDE 0281-12 (Designed according to) Insulation resistance: Min. 50 MΩ.km Rated voltage Uo/U: 300 / 500V Test voltage: 4000 V Temperature range: Fixed: - 40 oC ~ + 90 oC; Mobile: - 5 oC ~ + 90 oC Min. bending radius: Fixed: 4 x D; Mobile: 7,5 x D Flame retardance test: IEC 60332-1 & EN 50265-2-1 Oil test: IEC 60811-2-1
BIRTFLEX 515 CY

BIRTFLEX 515 CY

PVC INSULATED,SCREENED OIL RESISTANT 0,6/1 kV CONTROL CABLES These oil and flame resistant, rated voltage 0,6/1 kV, flexible cables are used in mechanical engineering for instrumentation and control equipment for tooling machinery production lines and flexible applications for free movement without tensile load and witout forced movement, in dry, moist and wet rooms. The screen above the inner sheat protects against external interference pulses and ensures an interference-free transmission, and transfer impedance is max. 250 ?/km at 30MHZ. These cables are not used for outdoor or underground installation. Conductor: Flexible copper wires, plain; IEC 60228 Class 5, TS/DIN EN 60228 Class 5 Insulation: PVC compound , TI2 Core identification: Acc. to TS/DIN EN 50334 black cores with white numerals with green/yellow from 3 cores Lay-up: Cores laid up in layers of optimum pitch Inner Sheath: PVC compound, TM2; RAL 7001,Grey Screen: Braid of tinned copper wires, 85% coverage Outer sheath: Oil and flame resistant PVC compound, TM5 Sheath colour: RAL 9005, Black Standard: TS HD 21.13 S1, DIN VDE 0281-13 (Designed according to) Insulation resistance: Min. 50 MΩ.km Rated voltage Uo/U: 0,6/1 kV Test voltage: 4000 V Temperature range: Fixed: - 40 oC ~ + 70 oC; Mobile: - 5 oC ~ + 70 oC Min. bending radius: Fixed: 6 x D; Mobile: 12,5 x D Flame retardance test: IEC 60332-1 & EN 50265-2-1 Oil test: IEC 60811-2-1 Transfer impedance: Max. 250 Ω/km at 30MHZ EMC: ELECTROMAGNETIC COMPATIBILITY
MC GC1300 pro22 Cat.7A S/FTP 4P LSHF-FR 500 m, Klasse Dca s2 d2 a1

MC GC1300 pro22 Cat.7A S/FTP 4P LSHF-FR 500 m, Klasse Dca s2 d2 a1

‧ 25 GBit / 10 GBit Installationskabel, simplex ‧ paargeschirmtes Installationskabel Cat.7A AWG 22 S/FTP ‧ 4 Paare (PiMF) ‧ Paarschirm: Kunststoff-Verbundfolie, Aluminium beschichtet ‧ Gesamtschirm: Cu-Geflecht verzinnt ‧ Kabelaußendurchmesser 7,5 - 8,1 mm ‧ Kabelmantelfarbe: blau ‧ Kopplungsdämpfung größer gleich 85 dB ‧ elektrische Daten getestet bis 1500 MHz ‧ GHMT Cat.7A PVP zertifiziert ‧ Geltende Normen: EN 50173-1, ISO/IEC 11801, EN 50288-9-1 und IEC 61156-5 ‧ Kabelmantel LSHF-FR (LSOH-FR) ‧ Flammwidrigkeit: IEC 60332-1, IEC 60332-3-24, IEC 60754-2 und IEC 61034 ‧ Brandverhalten: Klasse Dca s2 d2 a1 nach EN 50399 (Klassifizierung nach EN 13501-6) ‧ Liefereinheit: auf Trommel - 1000 m
BayCom® RailOptic® SFK LWL-Schienenfußkabel

BayCom® RailOptic® SFK LWL-Schienenfußkabel

RailOptic® SFK LWL-Schienenfußkabel sind für den Einsatz in TK-Anlagen vorgesehen. Sie können vorzugsweise direkt am Schienenfuß oder anderen schwingungs- und stoßbelasteten Bereichen verlegt werden, sind aber auch für die Verlegung in Erde, Trog- sowie Rohrkanälen geeignet. Die Verlegung von Kabeln am Schienenfuß ist eine kostengünstige Variante für den Einsatz in Kabelanlagen von Regional- und Nebenbahnen, für die Baufeldfreimachung und bei Störungen. Im Vergleich zu herkömmlichen Kabeltrassen reduziert sich der Planungs- und Montageaufwand erheblich, da keine Tiefbauarbeiten anfallen. Die Verlegung kann von qualifizierten Firmen ohne Spezialfahrzeuge, -Werkzeuge und mit Schienenfußklammern aus dem Standardprogramm durchgeführt werden. Das Kabelzubehör (Muffen, Abschlusskästen) stammt aus dem Standardprogramm der Fa. TE connectivity.RailOptic® SFK LWL-Schienenfußkabel sind universell einsetzbar und können bei Bedarf gemeinsam oder auch nachträglich mit BayRail® Kupferschienenfußkabel verlegt werden. Fertigung nach nationalen und internationalen Normen auf Anfrage. Kabel nach Kundenspezifikation auf Anfrage.
PV Drahtclips Metallkabelclips für Solarkabel - Solarkabelclips für PV Kabelmanagement

PV Drahtclips Metallkabelclips für Solarkabel - Solarkabelclips für PV Kabelmanagement

Solar Kabelclip (Bitte erkundigen Sie sich nach Details zu verschiedenen Modellen) Produkt-Spezifikationen Material: 301 Edelstahl Farbe: Weiß Verpackung: 100 Stück//Beutel 500 Stück//Beutel Umgebungstemperaturbereich: -40℃…+85℃ (IEC) SCC-ST/2 Geeignet für Kabel-OD: 2*4,0mm² Anwendung für Modul Material: 301 Edelstahl Farbe: Weiß Umgebungstemperaturbereich: -40℃…+85℃ (IEC)
1500VDC Solar Kabelstecker Kompatibel mc4 Evo2 10mm2

1500VDC Solar Kabelstecker Kompatibel mc4 Evo2 10mm2

1500VDC Solar Kabelstecker kompatibel mit mc4 Evo2 10mm2 Solar DC Stromstecker - NSPV PV4.0 Solar Kabelstecker 1500VDC Eigenschaften: TUV&CE zertifiziert; Importiertes PPE-Isoliermaterial; IP68 Schutzgrad bei 1m, 1H; Kompatibel mit MC4 Steckverbindern; Niedriger Kontaktwiderstand für ≤ 0,25 mΩ; Hohe Spannung für 1,5kV DC und hoher Strom für 60Amp. P.S.: 1,5-6sqmm mit Stanzstift und Drehstift, 10/16sqmm nur mit Drehstift. Isoliermaterial: PPE/PA Nennspannung: 1500VDC Nennstoßspannung: 12KV Prüfspannung: 8kV (50Hz, 1min) Kontaktwiderstand: ≤ 0,25 mΩ Kontaktmaterial: Kupfer, verzinnt Schutzgrad: IP68 (1m, 1H) Überspannungskategorie/Verschmutzungsgrad: CATIII/2 Regulatorische Genehmigung: TUV/CE (IEC62852:2014) Sicherheitsgrad: II Flammenklasse: UL94-V0 Installationsart: Außenbereich, UV-beständig (F1) Umgebungstemperaturbereich: -40℃…+85℃ (IEC) Geeignete Kabelquerschnitte: 1,5~10mm2/16~8AWG Verbindungssystem: Crimpverbindung Mutternkappen-Verriegelungskraft: 1,5-1,8Nm Obere Begrenzungstemperatur: 110℃ (IEC) Nennstoßspannung: 16kV
Photovoltaik Solar Kabelmanagement Clips Solar Panel Kabel C

Photovoltaik Solar Kabelmanagement Clips Solar Panel Kabel C

Solar Kabelclip (Bitte erkundigen Sie sich nach Details zu verschiedenen Modellen) Produkt-Spezifikationen Material: 301 Edelstahl Farbe: Weiß Verpackung: 100 Stück//Beutel 500 Stück//Beutel Umgebungstemperaturbereich: -40℃…+85℃ (IEC) SCC-90/6S/2 Geeignet für Kabel-OD: 90 Grad 2*6,0 mm² Anwendung für Modul 90 Grad Material: 301 Edelstahl Farbe: Weiß Umgebungstemperaturbereich: -40℃…+85℃ (IEC)
RE-2G(St)HSWAH-CI  FE180

RE-2G(St)HSWAH-CI FE180

HALOGEN-FREE FIRE RESISTANT (Cl) INSTRUMENTATION CABLES, EN 50288-7SINGLE & MULTI-TRIPLE, SILICONE INSULATED, COLLECTIVE SCREENED, ARMOURED, HFFR SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... These cables are used on the basis of a fixed operating mode, can continue with the supply of a power under the existing fire conditions and in the environments which have no corrosive gases are emitted in the event of fire. In case of fire, these cables inhibit the propagation of the flames whereby the development of smoke is extremely low. Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. With blue sheath it is suitable for intrinsically safe systems. The armour above the inner sheath protects the cable from mechanical shocks. These cables are recommended for direct burial. They are for indoor and outdoor installation, in dry and wet locations; on racks, trays, in conduits. Outer sheath: HFFR compound, EN 50290-2-27 Sheath colour: RAL 9005, Black or RAL 5015, Blue Conductor: Plain copper wire, stranded, IEC 60228 Sınıf 2, TS/DIN EN 60228 Sınıf 2 Insulation: Special silicone rubber compound Core identification: Black / Blue / Red cores are numbered, (1-1-1, 2-2-2,…), Upon request ; Colour coded according to IEC 60189-2, Other core configurations manufactured upon request. Pair: Two conductors twisted to a pair Lay-up: Triples laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over stranded tinned copper drain, wire 0,50 mm2 Inner sheath: HFFR compound, EN 50290-2-27 Armour: Galvenized round steel wire, EN 10257-1 Standard: TS/DIN EN 50288-7, (Designed according to) Conductor resistance: 0,50mm2 : 36,7 Ω/km, 0,75mm2 : 25,0 Ω/km, 1,0mm2 : 18,5 Ω/km, 1,3mm2 : 14,2 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km Capacitance unbalance: (1 kHz) : max. 500 pF/500 m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,30mm2 : 40 µH/Ω, 1,5mm2 : 40 µH/Ω Rated voltage: 500V Test voltage: Urms core-core : 2000 V, Urms core-screen : 2000 V Temperature range: operation : - 30 oC ~ + 90 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 10 x D Flame test: IEC 60332-1 & TS/DIN EN 60332-1, IEC 60332-3 & TS/DIN EN 50266-2-4 Smoke density test: IEC 61034-2 & TS/DIN EN 61034-2 Halogen-free properties test: IEC60754-1/2 & TS/DIN EN 50267-2 Circuit integrity (CI): IEC 60331 , VDE 0472-814, BS 6387 Cat. CWZ
Solarpanel-Drahtclips PV-Kabelclips Solar-Drahtmanagement - Silberne Edelstahlclips für Solar-Kabelmanagement

Solarpanel-Drahtclips PV-Kabelclips Solar-Drahtmanagement - Silberne Edelstahlclips für Solar-Kabelmanagement

Solar Kabelclip (Bitte erkundigen Sie sich nach Details zu verschiedenen Modellen) Produkt-Spezifikationen Material: 301 Edelstahl Farbe: Weiß Verpackung: 100 Stück//Beutel 500 Stück//Beutel Umgebungstemperaturbereich: -40℃…+85℃ (IEC) SCC-6S/4 Geeignet für Kabel-Ø: 4*6,0mm² Anwendung für Modul Material: 301 Edelstahl Farbe: Weiß Umgebungstemperaturbereich: -40℃…+85℃ (IEC) Verpackung: 100 Stück//Beutel
RE-2G(St)HSWAH-CI  FE180 MP

RE-2G(St)HSWAH-CI FE180 MP

HALOGEN-FREE FIRE RESISTANT (CI) INSTRUMENTATION CABLES, EN 50288-7SINGLE & MULTI-PAIR, SILICONE INSULATED, COLLECTIVE SCREENED, ARMOURED, HFFR SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... These cables are used on the basis of a fixed operating mode, can continue with the supply of a power under the existing fire conditions and in the environments which have no corrosive gases are emitted in the event of fire. In case of fire, these cables inhibit the propagation of the flames whereby the development of smoke is extremely low. Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. With blue sheath it is suitable for intrinsically safe systems. The armour above the inner sheath protects the cable from mechanical shocks. These cables are recommended for direct burial. They are for indoor and outdoor installation, in dry and wet locations; on racks, trays, in conduits. Conductor: Plain copper wire, stranded, IEC 60228 Sınıf 2, TS/DIN EN 60228 Sınıf 2 Insulation: Special silicone rubber compound Core identification: Black / Blue cores numbered 1-1, 2-2,…, Upon request ; Colour coded according to IEC 60189-2, Other core configurations manufactured upon request. Pair: Two conductors twisted to a pair Lay-up: Pairs laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over stranded tinned copper drain, wire 0,50 mm2 Inner sheath: HFFR compound, EN 50290-2-27 Armour: Galvenized round steel wire, EN 10257-1 Outer sheath: HFFR compound, EN 50290-2-27 Sheath colour: RAL 9005, Black or RAL 5015, Blue Standard: TS/DIN EN 50288-7, (Designed according to) Conductor resistance: 0,50mm2 : 36,7 Ω/km, 0,75mm2 : 25,0 Ω/km, 1,0mm2 : 18,5 Ω/km, 1,3mm2 : 14,2 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km Capacitance unbalance: (1 kHz) : max. 500 pF/500 m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,30mm2 : 40 µH/Ω, 1,5mm2 : 40 µH/Ω Rated voltage: 500V Test voltage: Urms core-core : 2000 V, Urms core-screen : 2000 V Temperature range: operation : - 30 oC ~ + 90 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 10 x D Flame test: IEC 60332-1 & TS/DIN EN 60332-1, IEC 60332-3 & TS/DIN EN 50266-2-4 Smoke density test: IEC 61034-2 & TS/DIN EN 61034-2 Halogen-free properties test: IEC60754-1/2 & TS/DIN EN 50267-2 Circuit integrity (CI): IEC 60331 , VDE 0472-814, BS 6387 Cat. CWZ
RE-2G(St)HSWAH-CI-TIMF  FE180

RE-2G(St)HSWAH-CI-TIMF FE180

HALOGEN-FREE FIRE RESISTANT (CI) INSTRUMENTATION CABLES, EN 50288-7MULTI-TRIPLE, SILICONE INSULATED, INDIVIDUAL & COLLECTIVE SCREENED, ARMOURED, HFFR SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... These cables are used on the basis of a fixed operating mode, can continue with the supply of a power under the existing fire conditions and in the environments which have no corrosive gases are emitted in the event of fire. In case of fire, these cables inhibit the propagation of the flames whereby the development of smoke is extremely low. Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. With blue sheath it is suitable for intrinsically safe systems. The armour above the inner sheath protects the cable from mechanical shocks. These cables are recommended for direct burial. They are for indoor and outdoor installation, in dry and wet locations; on racks, trays, in conduits. Conductor: Plain copper wire, stranded, IEC 60228 Sınıf 2, TS/DIN EN 60228 Sınıf 2 Insulation: Special silicone rubber compound Core identification: Black / Blue / Red; with numbered tape under, separator tape of the pair screen, Upon request ; Black / Blue / Red cores numbered 1-1-1, 2-2-2,…, Other core configurations manufactured upon request. Triple: Three conductors twisted to a triple TIMF Construction: Polyester tape above the triple, AL-PES tape, over solid tinned copper drain wire, 0,60 mm, Upon request ; Stranded 0,50 mm2 copper drain wire Lay-up: TIMF laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over stranded tinned copper drain, wire 0,50 mm2 Inner sheath: HFFR compound, EN 50290-2-27 Armour: Galvenized round steel wire, EN 10257-1 Outer sheath: HFFR compound, EN 50290-2-27 Sheath colour: RAL 9005, Black or RAL 5015, Blue Rated voltage: 500V Test voltage: Urms core-core : 2000 V, Urms core-screen : 2000 V Temperature range: operation : - 30 oC ~ + 90 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 10 x D Flame test: IEC 60332-1 & TS/DIN EN 60332-1, IEC 60332-3 & TS/DIN EN 50266-2-4 Smoke density test: IEC 61034-2 & TS/DIN EN 61034-2 Halogen-free properties test: IEC60754-1/2 & TS/DIN EN 50267-2 Circuit integrity (CI): IEC 60331 , VDE 0472-814, BS 6387 Cat. CWZ Standard: TS/DIN EN 50288-7, (Designed according to) Conductor resistance: 0,50mm2 : 36,7 Ω/km, 0,75mm2 : 25,0 Ω/km, 1,0mm2 : 18,5 Ω/km, 1,3mm2 : 14,2 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 300 MΩ.km Mutual Capacitance: max. 150 pF/m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,30mm2 : 40 µH/Ω, 1,5mm2 : 40 µH/Ω
RE-2G(St)H-CI  FE180

RE-2G(St)H-CI FE180

HALOGEN-FREE FIRE RESISTANT (CI) INSTRUMENTATION CABLES, EN 50288-7SINGLE & MULTI-TRIPLE, SILICONE INSULATED, COLLECTIVE SCREENED, HFFR SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... These cables are used on the basis of a fixed operating mode, can continue with the supply of a power under the existing fire conditions and in the environments which have no corrosive gases are emitted in the event of fire. In case of fire, these cables inhibit the propagation of the flames whereby the development of smoke is extremely low. Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. With blue sheath it is suitable for intrinsically safe systems. These cables are not recommended for direct burial. They are for indoor and outdoor installation, in dry and wet locations; on racks, trays, in conduits. Conductor: Plain copper wire, stranded, IEC 60228 Sınıf 2, TS/DIN EN 60228 Sınıf 2 Insulation: Special silicone rubber compound Core identification: Black / Blue / Red cores are numbered, (1-1-1, 2-2-2,…), Upon request ; Colour coded according to IEC 60189-2, Other core configurations manufactured upon request. Triple: Three conductors twisted to a triple Lay-up: Triples laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over stranded tinned copper drain, wire 0,50 mm2 Outer sheath: HFFR compound, EN 50290-2-27 Sheath colour: RAL 9005, Black or RAL 5015, Blue Standard: TS/DIN EN 50288-7, (Designed according to) Conductor resistance: 0,50mm2 : 36,7 Ω/km, 0,75mm2 : 25,0 Ω/km, 1,0mm2 : 18,5 Ω/km, 1,3mm2 : 14,2 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km Capacitance unbalance: (1 kHz) : max. 500 pF/500 m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,30mm2 : 40 µH/Ω, 1,5mm2 : 40 µH/Ω Rated voltage: 500V Test voltage: Urms core-core : 2000 V, Urms core-screen : 2000 V Temperature range: operation : - 30 oC ~ + 90 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 7,5 x D Flame test: IEC 60332-1 & TS/DIN EN 60332-1, IEC 60332-3 & TS/DIN EN 50266-2-4 Smoke density test: IEC 61034-2 & TS/DIN EN 61034-2 Halogen-free properties test: IEC60754-1/2 & TS/DIN EN 50267-2 Circuit integrity (CI): IEC 60331 , VDE 0472-814, BS 6387 Cat. CWZ
RE-2G(St)H-CI-PIMF  FE180

RE-2G(St)H-CI-PIMF FE180

HALOGEN-FREE FIRE RESISTANT (CI) INSTRUMENTATION CABLES, EN 50288-7MULTI-PAIR, SILICONE INSULATED, INDIVIDUAL & COLLECTIVE SCREENED, HFFR SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... These cables are used on the basis of a fixed operating mode, can continue with the supply of a power under the existing fire conditions and in the environments which have no corrosive gases are emitted in the event of fire. In case of fire, these cables inhibit the propagation of the flames whereby the development of smoke is extremely low. Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. With blue sheath it is suitable for intrinsically safe systems. These cables are not recommended for direct burial. They are for indoor and outdoor installation, in dry and wet locations; on racks, trays, in conduits. Core identification: Black / Blue ; with numbered tape under , separator tape of the pair screen, Upon request ; Black / Blue cores numbered 1-1, 2-2,…, Other core configurations manufactured upon request. Pair: Two conductors twisted to a pair PIMF Construction: Polyester tape above the pair, AL-PES tape, over solid tinned copper drain wire, 0,60 mm, pon request ; Stranded 0,50 mm2 copper drain wire Lay-up: PIMF laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over stranded tinned copper drain, wire 0,50 mm2 Outer sheath: HFFR compound, EN 50290-2-27 Sheath colour: RAL 9005, Black or RAL 5015, Blue Conductor: Plain copper wire, stranded, IEC 60228 Sınıf 2, TS/DIN EN 60228 Sınıf 2 Insulation: Special silicone rubber compound Standard: TS/DIN EN 50288-7, (Designed according to) Conductor resistance: 0,50mm2 : 36,7 Ω/km, 0,75mm2 : 25,0 Ω/km, 1,0mm2 : 18,5 Ω/km, 1,3mm2 : 14,2 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 300 MΩ.km Mutual Capacitance: max. 150 pF/m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,30mm2 : 40 µH/Ω, 1,5mm2 : 40 µH/Ω Rated voltage: 500V Test voltage: Urms core-core : 2000 V, Urms core-screen : 2000 V Temperature range: operation : - 30 oC ~ + 90 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 7,5 x D Flame test: IEC 60332-1 & TS/DIN EN 60332-1, IEC 60332-3 & TS/DIN EN 50266-2-4 Smoke density test: IEC 61034-2 & TS/DIN EN 61034-2 Halogen-free properties test: IEC60754-1/2 & TS/DIN EN 50267-2 Circuit integrity (CI): IEC 60331 , VDE 0472-814, BS 6387 Cat. CWZ
PV 301 Edelstahl Solarpanel Kabelclips PV Kabelmanagement

PV 301 Edelstahl Solarpanel Kabelclips PV Kabelmanagement

Solar Kabelclip (Bitte erkundigen Sie sich nach Details zu verschiedenen Modellen)\nProdukt-Spezifikationen\nMaterial: 301 Edelstahl\nFarbe: Weiß\nVerpackung: 100 Stück//Beutel\n 500 Stück//Beutel\nUmgebungstemperaturbereich: -40℃…+85℃ (IEC)\nSCC-90/US/2\n\nMaterial: 301 Edelstahl\nFarbe: Weiß\nUmgebungstemperaturbereich: -40℃…+85℃ (IEC)\nVerpackung: 100 Stück//Beutel
LWL-Universalkabel 50/125µ OM2

LWL-Universalkabel 50/125µ OM2

U-DQ(ZN) BH 50/125µ OM2 Faser geeignet zur Innen- und Außenverlegung verlegbar in Kabelpritschen, Rohrleitungen, Kabelkanälen Nagetierschutz, halogenfrei, längswasserdicht, metallfrei LSZH Mantel schwarz UV-beständig Gel gefüllte Bündelader, 250µ farbige Faserbeschichtung IEC 60332-1, Raucharm IEC 61034, IEC 11801, EN50173 geliefert wird auf Einwegtrommel oder als Kabelring
LWL-Universalkabel LC-LC

LWL-Universalkabel LC-LC

Konfektioniertes LWL Universalkabel inklusive Einzugshilfe LC-Stecker auf LC-Stecker Montagefertig inkl. Dämpfungsprotokoll Konfektionierte beschriftete abgestufte Kabelpeitschen Werksseitige Fertigung inkl. Politur und Funktionstest Zugentlastung durch Kabelaufteiler 15,5mm Durchmesser geliefert auf Einwegtrommel oder als Kabelring Kabel: U-DQ(ZN) BH geeignet zur Innen- und Außenverlegung verlegbar in Kabelpritschen, Rohrleitungen, Kabelkanälen Nagetierschutz, halogenfrei, längswasserdicht, metallfrei LSZH Mantel schwarz UV-beständig Gel gefüllte Bündelader, 250µ farbige Faserbeschichtung IEC 60332-1, Raucharm IEC 61034, IEC 11801, EN50173 inkl. Einzugshilfe 40mm Durchmesser wiederverwendbar Außendurchmesser des Aufteilers: 15,5mm Außendurchmesser der Einzugshilfe: 40mm
Telass BK-Verteiler- und Linienkabel

Telass BK-Verteiler- und Linienkabel

Verteiler- und Linienkabel werden in Breitband-Kommunikations-(BK-)Netzen genutzt. Längsgeschweißte hochreine Kupferrohre sorgen für optimale Störstrahlsicherheit sowie hohe Stabilität. bedea Bambus (TELASS® R/LR) BK-Kabel werden in Breitband-Kommunikations-(BK-)Netzen genutzt. Sie dienen der Signalübertragung zwischen Kopfstation und Hausanschluss. Die Kabel entsprechen DIN EN 50117-2-2 (Hausanschlusskabel) bzw. DIN EN 50117-2-3 (Verteiler- und Linienkabel) und sind typgeprüft nach FTZ-Norm (6145–3300). 'CPR/DOP: Fca Typ: Telass CR 170 Artikelnummer: 31640300 Mantelmaterial: PE Durchmesser: 10,0 mm Aufmachung: Meterlänge
Telass BK-Verteiler- und Linienkabel

Telass BK-Verteiler- und Linienkabel

Verteiler- und Linienkabel werden in Breitband-Kommunikations-(BK-)Netzen genutzt. Längsgeschweißte hochreine Kupferrohre sorgen für optimale Störstrahlsicherheit sowie hohe Stabilität. bedea Bambus (TELASS® R/LR) BK-Kabel werden in Breitband-Kommunikations-(BK-)Netzen genutzt. Sie dienen der Signalübertragung zwischen Kopfstation und Hausanschluss. Die Kabel entsprechen DIN EN 50117-2-2 (Hausanschlusskabel) bzw. DIN EN 50117-2-3 (Verteiler- und Linienkabel) und sind typgeprüft nach FTZ-Norm (6145–3300). 'CPR/DOP: Fca Typ: Telass CR 170 Artikelnummer: 31640900 Mantelmaterial: PE Durchmesser: 10,0 mm Aufmachung: Meterlänge
Telass BK-Verteiler- und Linienkabel

Telass BK-Verteiler- und Linienkabel

Verteiler- und Linienkabel werden in Breitband-Kommunikations-(BK-)Netzen genutzt. Längsgeschweißte hochreine Kupferrohre sorgen für optimale Störstrahlsicherheit sowie hohe Stabilität. bedea Bambus (TELASS® R/LR) BK-Kabel werden in Breitband-Kommunikations-(BK-)Netzen genutzt. Sie dienen der Signalübertragung zwischen Kopfstation und Hausanschluss. Die Kabel entsprechen DIN EN 50117-2-2 (Hausanschlusskabel) bzw. DIN EN 50117-2-3 (Verteiler- und Linienkabel) und sind typgeprüft nach FTZ-Norm (6145–3300). 'CPR/DOP: Fca Typ: Telass CR 330 Artikelnummer: 31650900 Mantelmaterial: PE Durchmesser: 17,0 mm Aufmachung: Meterlänge
Telass BK-Verteiler- und Linienkabel

Telass BK-Verteiler- und Linienkabel

Verteiler- und Linienkabel werden in Breitband-Kommunikations-(BK-)Netzen genutzt. Längsgeschweißte hochreine Kupferrohre sorgen für optimale Störstrahlsicherheit sowie hohe Stabilität. bedea Bambus (TELASS® R/LR) BK-Kabel werden in Breitband-Kommunikations-(BK-)Netzen genutzt. Sie dienen der Signalübertragung zwischen Kopfstation und Hausanschluss. Die Kabel entsprechen DIN EN 50117-2-2 (Hausanschlusskabel) bzw. DIN EN 50117-2-3 (Verteiler- und Linienkabel) und sind typgeprüft nach FTZ-Norm (6145–3300). 'CPR/DOP: Fca Typ: Telass LR 170 Artikelnummer: 28390900 Mantelmaterial: PE Durchmesser: 10,0 mm Aufmachung: Meterlänge
Telass BK-Verteiler- und Linienkabel

Telass BK-Verteiler- und Linienkabel

Verteiler- und Linienkabel werden in Breitband-Kommunikations-(BK-)Netzen genutzt. Längsgeschweißte hochreine Kupferrohre sorgen für optimale Störstrahlsicherheit sowie hohe Stabilität. bedea Bambus (TELASS® R/LR) BK-Kabel werden in Breitband-Kommunikations-(BK-)Netzen genutzt. Sie dienen der Signalübertragung zwischen Kopfstation und Hausanschluss. Die Kabel entsprechen DIN EN 50117-2-2 (Hausanschlusskabel) bzw. DIN EN 50117-2-3 (Verteiler- und Linienkabel) und sind typgeprüft nach FTZ-Norm (6145–3300). 'CPR/DOP: Fca Typ: Telass LR 490 Artikelnummer: 27450900 Mantelmaterial: PE Durchmesser: 24,5 mm Aufmachung: Meterlänge
Telass BK-Verteiler- und Linienkabel

Telass BK-Verteiler- und Linienkabel

Verteiler- und Linienkabel werden in Breitband-Kommunikations-(BK-)Netzen genutzt. Längsgeschweißte hochreine Kupferrohre sorgen für optimale Störstrahlsicherheit sowie hohe Stabilität. bedea Bambus (TELASS® R/LR) BK-Kabel werden in Breitband-Kommunikations-(BK-)Netzen genutzt. Sie dienen der Signalübertragung zwischen Kopfstation und Hausanschluss. Die Kabel entsprechen DIN EN 50117-2-2 (Hausanschlusskabel) bzw. DIN EN 50117-2-3 (Verteiler- und Linienkabel) und sind typgeprüft nach FTZ-Norm (6145–3300). 'CPR/DOP: Fca Typ: Telass CR 475 Artikelnummer: 37910900 Mantelmaterial: PE Durchmesser: 24,5 mm Aufmachung: Meterlänge
Telass BK-Verteiler- und Linienkabel

Telass BK-Verteiler- und Linienkabel

Verteiler- und Linienkabel werden in Breitband-Kommunikations-(BK-)Netzen genutzt. Längsgeschweißte hochreine Kupferrohre sorgen für optimale Störstrahlsicherheit sowie hohe Stabilität. bedea Bambus (TELASS® R/LR) BK-Kabel werden in Breitband-Kommunikations-(BK-)Netzen genutzt. Sie dienen der Signalübertragung zwischen Kopfstation und Hausanschluss. Die Kabel entsprechen DIN EN 50117-2-2 (Hausanschlusskabel) bzw. DIN EN 50117-2-3 (Verteiler- und Linienkabel) und sind typgeprüft nach FTZ-Norm (6145–3300). 'CPR/DOP: Fca Typ: Telass LR 220 Artikelnummer: 10030900 Mantelmaterial: PE Durchmesser: 12,5 mm Aufmachung: Meterlänge
LWL-Universalkabel 9/125µ OS2

LWL-Universalkabel 9/125µ OS2

U-DQ(ZN) BH 9/125µ OS2 / G657A1 Faser geeignet zur Innen- und Außenverlegung verlegbar in Kabelpritschen, Rohrleitungen, Kabelkanälen Nagetierschutz, halogenfrei, längswasserdicht, metallfrei LSZH Mantel schwarz UV-beständig Gel gefüllte Bündelader, 250µ farbige Faserbeschichtung IEC 60332-1, Raucharm IEC 61034, IEC 11801, EN50173 geliefert wird auf Einwegtrommel oder als Kabelring
LWL-Universalkabel E2000-E2000

LWL-Universalkabel E2000-E2000

Konfektioniertes LWL Universalkabel inklusive Einzugshilfe E2000-Stecker auf E2000-Stecker Montagefertig inkl. Dämpfungsprotokoll Konfektionierte beschriftete abgestufte Kabelpeitschen Werksseitige Fertigung inkl. Politur und Funktionstest Zugentlastung durch Kabelaufteiler 15,5mm Durchmesser geliefert auf Einwegtrommel oder als Kabelring Kabel: U-DQ(ZN) BH geeignet zur Innen- und Außenverlegung verlegbar in Kabelpritschen, Rohrleitungen, Kabelkanälen Nagetierschutz, halogenfrei, längswasserdicht, metallfrei LSZH Mantel schwarz UV-beständig Gel gefüllte Bündelader, 250µ farbige Faserbeschichtung IEC 60332-1, Raucharm IEC 61034, IEC 11801, EN50173 inkl. Einzugshilfe 40mm Durchmesser wiederverwendbar Außendurchmesser des Aufteilers: 15,5mm Außendurchmesser der Einzugshilfe: 40mm
LWL-Universalkabel ST-ST

LWL-Universalkabel ST-ST

Konfektioniertes LWL Universalkabel inklusive Einzugshilfe ST-Stecker auf ST-Stecker Montagefertig inkl. Dämpfungsprotokoll Konfektionierte beschriftete abgestufte Kabelpeitschen Werksseitige Fertigung inkl. Politur und Funktionstest Zugentlastung durch Kabelaufteiler 15,5mm Durchmesser geliefert auf Einwegtrommel oder als Kabelring Kabel: U-DQ(ZN) BH geeignet zur Innen- und Außenverlegung verlegbar in Kabelpritschen, Rohrleitungen, Kabelkanälen Nagetierschutz, halogenfrei, längswasserdicht, metallfrei LSZH Mantel schwarz UV-beständig Gel gefüllte Bündelader, 250µ farbige Faserbeschichtung IEC 60332-1, Raucharm IEC 61034, IEC 11801, EN50173 inkl. Einzugshilfe 40mm Durchmesser wiederverwendbar Außendurchmesser des Aufteilers: 15,5mm Außendurchmesser der Einzugshilfe: 40mm